{"id":16188,"date":"2025-10-07T21:38:39","date_gmt":"2025-10-07T13:38:39","guid":{"rendered":"https:\/\/www.aokaifilters.com\/?page_id=16188"},"modified":"2025-10-20T11:42:11","modified_gmt":"2025-10-20T03:42:11","slug":"filter-bag-testing-analysis","status":"publish","type":"page","link":"https:\/\/www.aokaifilters.com\/tr\/services\/filter-bag-testing-analysis\/","title":{"rendered":"Filter Bag Testing &#038; Analysis"},"content":{"rendered":"<section class=\"l-section wpb_row us_custom_209d813c height_custom with_img parallax_ver\"><div class=\"l-section-img\" role=\"img\" aria-label=\"Torba Kontrol ve Bak\u0131m\u0131\" data-img-width=\"1544\" data-img-height=\"621\" style=\"background-image: url(https:\/\/www.aokaifilters.com\/wp-content\/uploads\/2023\/08\/service-5.jpg);background-position: top center;background-repeat: no-repeat;background-size: auto;\"><\/div><div class=\"l-section-overlay\" style=\"background:rgba(58,61,37,0.20)\"><\/div><div class=\"l-section-h i-cf\"><div class=\"g-cols vc_row via_grid cols_1 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><nav class=\"g-breadcrumbs us_custom_2509bbe8 has_text_color separator_icon align_center hide_current\" itemscope itemtype=\"http:\/\/schema.org\/BreadcrumbList\"><div class=\"g-breadcrumbs-item\" itemscope itemprop=\"itemListElement\" itemtype=\"http:\/\/schema.org\/ListItem\"><a itemprop=\"item\" href=\"https:\/\/www.aokaifilters.com\/tr\/\"><span itemprop=\"name\">Giri\u015f<\/span><\/a><meta itemprop=\"position\" content=\"1\"\/><\/div><div class=\"g-breadcrumbs-separator\"><i class=\"far fa-angle-right\"><\/i><\/div><div class=\"g-breadcrumbs-item\">Sayfalar<\/div><\/nav><div class=\"w-separator size_medium\"><\/div><h1 class=\"w-post-elm post_title us_custom_8b3d6790 has_text_color align_center color_link_inherit\">Filter Bag Testing &#038; Analysis<\/h1><\/div><\/div><\/div><\/div><\/section><section class=\"l-section wpb_row height_medium\"><div class=\"l-section-h i-cf\"><div class=\"g-cols vc_row via_grid cols_2 laptops-cols_inherit tablets-cols_1 mobiles-cols_1 valign_top type_default stacking_default\" style=\"--columns-gap:5rem;\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-text us_custom_39fbd8f9 has_text_color\"><span class=\"w-text-h\"><span class=\"w-text-value\">Filter Bag Testing &amp; Analysis<\/span><\/span><\/div><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><h2>Service Objectives<\/h2>\n<p>Is your dust collector underperforming? Are you facing unexpected filter bag failures or struggling with high energy costs? Do you know what media to choose and when to replace your filter bags? Aokai Environtec&#8217;s Filter Bag Testing &amp; Analysis Service (also known as Filter Bag Failure Analysis Service, depending on the service objectives) provides the scientific data you need to maximize the life and efficiency of your filtration system.<\/p>\n<h3>Key Service Objectives:<\/h3>\n<\/div><\/div><div class=\"w-separator size_medium\"><\/div><div class=\"w-tabs us_custom_07146db5 has_text_color style_default switch_click accordion remove_indents\" style=\"--sections-title-size:20px\"><div class=\"w-tabs-sections titles-align_none icon_chevron cpos_right\"><div class=\"w-tabs-section\" id=\"ca58\"><button class=\"w-tabs-section-header\" aria-controls=\"content-ca58\" aria-expanded=\"false\"><h4 class=\"w-tabs-section-title\">Failure Diagnosis and Root Cause Analysis<\/h4><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-ca58\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><ul>\n<li><strong>Key question answered<\/strong>: What is the root cause of premature bag failure, and how to eliminate it?<\/li>\n<li><strong>Value to customers<\/strong>: Prevents future unexpected downtime and costly emergency replacements.<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><div class=\"w-tabs-section\" id=\"zb6e\"><button class=\"w-tabs-section-header\" aria-controls=\"content-zb6e\" aria-expanded=\"false\"><h4 class=\"w-tabs-section-title\">Performance Optimization<\/h4><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-zb6e\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><ul>\n<li><strong>Key question answered<\/strong>: What is causing the abnormally high differential pressure, and what system adjustments will restore airflow efficiency?<\/li>\n<li><strong>Value to customers<\/strong>: Lowers energy consumption and maximizes the throughput and dust filtration efficiency.<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><div class=\"w-tabs-section\" id=\"vc8c\"><button class=\"w-tabs-section-header\" aria-controls=\"content-vc8c\" aria-expanded=\"false\"><h4 class=\"w-tabs-section-title\">Maintenance Planning &amp; Guidance<\/h4><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-vc8c\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><ul>\n<li><strong>Key question answered<\/strong>: What is the filter bag&#8217;s remaining useful life, and what upgraded media to choose for the next replacement?<\/li>\n<li><strong>Value to customers<\/strong>: Enables planned maintenance, avoids reactive shutdowns, and ensures future media selections are optimal for the application.<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-text us_custom_39fbd8f9 has_text_color\"><span class=\"w-text-h\"><span class=\"w-text-value\">Filter Bag Testing &amp; Analysis<\/span><\/span><\/div><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><h2>Service Descriptions<\/h2>\n<p data-start=\"208\" data-end=\"628\">By conducting thorough filter bag testing and analysis, you can gain valuable insights into your filtration system\u2019s condition and ensure peak performance. A systematic approach deepens your understanding of the ideal match between filter bag materials and filtration applications, empowering you to implement more effective and long-lasting solutions.<\/p>\n<h3 data-start=\"208\" data-end=\"628\">Testing Procedures:<\/h3>\n<\/div><\/div><div class=\"w-separator size_medium\"><\/div><div class=\"w-tabs us_custom_07146db5 has_text_color style_default switch_click accordion remove_indents\" style=\"--sections-title-size:20px\"><div class=\"w-tabs-sections titles-align_none icon_chevron cpos_right\"><div class=\"w-tabs-section\" id=\"w63a\"><button class=\"w-tabs-section-header\" aria-controls=\"content-w63a\" aria-expanded=\"false\"><h4 class=\"w-tabs-section-title\">Visual Inspection &amp; Measurement<\/h4><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-w63a\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><p>This procedure involves:<\/p>\n<ul>\n<li>Examine the failed bags for visible signs of damage like tears,\u00a0holes,\u00a0abrasion,\u00a0or caking.<\/li>\n<li>Assess the dust cake build-up and its characteristics (thickness,\u00a0texture,\u00a0adhesion).<\/li>\n<li>Look for evidence of chemical degradation or discoloration.<\/li>\n<li>Collect filter bag specs information, such as length, width, construction &amp; design.<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><div class=\"w-tabs-section\" id=\"c758\"><button class=\"w-tabs-section-header\" aria-controls=\"content-c758\" aria-expanded=\"false\"><h4 class=\"w-tabs-section-title\">Standard Physical &amp; Analytical Testing<\/h4><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-c758\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><p>We provide comprehensive, laboratory-based analysis to determine the precise condition and cause of failure for your filter media. Our standard testing protocols adhere to international standards.<\/p>\n<ul>\n<li><strong>Physical Integrity<\/strong>: Measures resistance to pulling and shock forces. Quantifies fiber degradation and estimated remaining strength. Key data provided includes weight &amp; thickness, tensile strength, and Mullen burst strength.<\/li>\n<li><strong>Performance Status<\/strong>: Measures the filter&#8217;s airflow capacity (air permeability). Indicates the severity of filter media blinding.<\/li>\n<li><strong>Microscopy &amp; Chemical<\/strong>: Diagnoses the root cause of failure (invisible damage). Identifies corrosive and abrasive agents, and evidence of thermal damage. Technologies used include SEM (Scanning Electron Microscopy), FTIR (Fourier-Transform Infrared Spectroscopy), and EDS (Energy-Dispersive X-ray Spectroscopy).<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><div class=\"w-tabs-section\" id=\"c872\"><button class=\"w-tabs-section-header\" aria-controls=\"content-c872\" aria-expanded=\"false\"><h4 class=\"w-tabs-section-title\">Advanced Analytic Testing (Premium)<\/h4><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-c872\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><p>Our laboratory is equipped with state-of-the-art apparatus. For clients requiring the highest level of predictive certainty and performance guarantee, we offer specialized testing:<\/p>\n<ul>\n<li><strong>VDI Testing<\/strong>: To measure baghouse filter media performance under defined conditions, such as air velocity, particle size &amp; distribution, differential pressure (dP), and cleaning intensity &amp; cycle. The test complies with internationally recognized standards (<span>VDI 3926 &amp; <\/span><span>ASTM D6830-02).<\/span><\/li>\n<li><strong>Pilot Baghouse Testing<\/strong>:\u00a0 The custom-built pilot baghouse evaluates filtration efficiency under controlled conditions, including dust loading, air velocity, and pulse-cleaning parameters.<\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><div class=\"w-tabs-section\" id=\"c951\"><button class=\"w-tabs-section-header\" aria-controls=\"content-c951\" aria-expanded=\"false\"><h4 class=\"w-tabs-section-title\">Data Analysis &amp; Reporting<\/h4><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content us_custom_fca8cc99\" id=\"content-c951\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><p>The test data is reviewed and interpreted by a team of skilled filtration engineers. Based on the collected evidence and analysis findings, a report is compiled outlining identified failures, test data, analytical results &amp; root causes, and recommendations for corrective actions and preventive measures.<\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"l-section wpb_row height_auto\"><div class=\"l-section-h i-cf\"><div class=\"g-cols vc_row via_grid cols_1 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-separator size_small with_line width_50 thick_2 style_solid color_border align_center\"><div class=\"w-separator-h\"><\/div><\/div><\/div><\/div><\/div><\/div><\/section><section class=\"l-section wpb_row height_medium\"><div class=\"l-section-overlay\" style=\"background:var(--color-content-bg)\"><\/div><div class=\"l-section-h i-cf\"><div class=\"g-cols vc_row via_grid cols_1 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-text us_custom_39fbd8f9 has_text_color\"><span class=\"w-text-h\"><span class=\"w-text-value\">Filter Bag Testing &amp; Analysis<\/span><\/span><\/div><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><h2>Testing Equipment<\/h2>\n<p>At Aokai Environtec, we are equipped with the most advanced testing equipment:<\/p>\n<\/div><\/div><div class=\"w-separator size_medium\"><\/div><div class=\"w-tabs us_custom_447bff20 layout_hor style_simple3 switch_click has_scrolling remove_indents\" style=\"--sections-title-size:1em\"><div class=\"w-tabs-list items_5 align_justify\"><div class=\"w-tabs-list-h\"><button class=\"w-tabs-item active with_icon\" aria-controls=\"content-w119\" aria-expanded=\"false\"><i class=\"fas fa-clipboard-list\"><\/i><span class=\"w-tabs-item-title\">Hava Ge\u00e7irgenli\u011fi<\/span><\/button><button class=\"w-tabs-item with_icon\" aria-controls=\"content-d8b9\" aria-expanded=\"false\"><i class=\"fas fa-clipboard-list\"><\/i><span class=\"w-tabs-item-title\">VDI 3926<\/span><\/button><button class=\"w-tabs-item with_icon\" aria-controls=\"content-efe0\" aria-expanded=\"false\"><i class=\"fas fa-clipboard-list\"><\/i><span class=\"w-tabs-item-title\">Pilot Baghouse<\/span><\/button><button class=\"w-tabs-item with_icon\" aria-controls=\"content-y714\" aria-expanded=\"false\"><i class=\"fas fa-clipboard-list\"><\/i><span class=\"w-tabs-item-title\">\u00c7ekme Dayan\u0131m\u0131<\/span><\/button><button class=\"w-tabs-item with_icon\" aria-controls=\"content-we21\" aria-expanded=\"false\"><i class=\"fas fa-clipboard-list\"><\/i><span class=\"w-tabs-item-title\">Microscopic Analysis<\/span><\/button><\/div><\/div><div class=\"w-tabs-sections titles-align_none icon_chevron cpos_right\"><div class=\"w-tabs-section active\" id=\"w119\" style=\"background:var(--color-content-bg);\"><button class=\"w-tabs-section-header active with_icon\" aria-controls=\"content-w119\" aria-expanded=\"true\"><i class=\"fas fa-clipboard-list\"><\/i><div class=\"w-tabs-section-title\">Hava Ge\u00e7irgenli\u011fi<\/div><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-w119\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"g-cols wpb_row us_custom_80ebc385 via_grid cols_2 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\" style=\"--columns-gap:5rem;\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-image us_custom_447bff20 has_ratio align_none\"><div class=\"w-image-h\"><div style=\"padding-bottom:100%\"><\/div><img decoding=\"async\" width=\"500\" height=\"499\" src=\"https:\/\/www.aokaifilters.com\/wp-content\/uploads\/2023\/09\/permeability-testing-1.jpg\" class=\"attachment-us_600_600 size-us_600_600\" alt=\"FX3300-IV Air Permeability Tester (Switzerland)\" loading=\"lazy\" title=\"\"><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><h3>Permeability Test<\/h3>\n<p><strong>Permeability Test<\/strong> measures the volumetric flow rate, measured in cubic feet per minute (cfm), through a square foot of filter media at a prescribed differential pressure.<\/p>\n<p>The measurement is performed on the filter in the \u201cas-received\u201d condition and after various cleaning steps, such as lightly snapping and brushing the filtration surface to simulate a cleaning cycle. The backside (clean side) of the filter media is vacuumed as the final step. An increase in the permeability indicates dust contamination.<\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"w-tabs-section\" id=\"d8b9\" style=\"background:var(--color-content-bg);\"><button class=\"w-tabs-section-header with_icon\" aria-controls=\"content-d8b9\" aria-expanded=\"false\"><i class=\"fas fa-clipboard-list\"><\/i><div class=\"w-tabs-section-title\">VDI 3926<\/div><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-d8b9\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"g-cols wpb_row us_custom_80ebc385 via_grid cols_2 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\" style=\"--columns-gap:3rem;\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-image us_custom_447bff20 has_ratio align_none\"><div class=\"w-image-h\"><div style=\"padding-bottom:100%\"><\/div><img decoding=\"async\" width=\"600\" height=\"498\" src=\"https:\/\/www.aokaifilters.com\/wp-content\/uploads\/2023\/09\/vdi-1-600x498.jpg\" class=\"attachment-us_600_600 size-us_600_600\" alt=\"Filter Media Testing &amp; Analysis\" loading=\"lazy\" title=\"\"><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><h3>VDI 3926 Test<\/h3>\n<p><strong>VDI 3926 Test<\/strong> is to simulate the real-world, cyclical operation of a filter to determine its long-term performance. The test involves:<\/p>\n<ol start=\"1\">\n<li>Cyclic Operation: Running the filter media through repeated cycles of dust loading\u00a0and cleaning under controlled conditions.<\/li>\n<li>Long-Term Performance: Evaluating critical parameters over many cycles, which include:\n<ul>\n<li>The <b>residual pressure drop<\/b> after cleaning (a measure of cleanability).<\/li>\n<li>The <b>filtration efficiency<\/b> ve <b>particulate emissions<\/b>.<\/li>\n<li>The <b>cycle time<\/b> until cleaning is required.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"w-tabs-section\" id=\"efe0\" style=\"background:var(--color-content-bg);\"><button class=\"w-tabs-section-header with_icon\" aria-controls=\"content-efe0\" aria-expanded=\"false\"><i class=\"fas fa-clipboard-list\"><\/i><div class=\"w-tabs-section-title\">Pilot Baghouse<\/div><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-efe0\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"g-cols wpb_row us_custom_80ebc385 via_grid cols_2 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\" style=\"--columns-gap:3rem;\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-image us_custom_447bff20 has_ratio align_none\"><div class=\"w-image-h\"><div style=\"padding-bottom:100%\"><\/div><img decoding=\"async\" width=\"600\" height=\"450\" src=\"https:\/\/www.aokaifilters.com\/wp-content\/uploads\/pilot-baghouse-1-600x450.webp\" class=\"attachment-us_600_600 size-us_600_600\" alt=\"\" loading=\"lazy\" title=\"\"><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><h3>Pilot Baghouse Test<\/h3>\n<p>A <b>Pilot Baghouse Test<\/b> offers customers a powerful way to test their filter bags or validate new media against representative process conditions. By utilizing a small-scale baghouse, the service allows us to test filter bags along with either a sample of actual dust or a standardized simulant dust to rigorously assess bag performance. This testing yields vital data on filtration efficiency, pressure drop, and bag life, enabling the customer to choose the best filter media and optimize their full-scale baghouse operations.<\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"w-tabs-section\" id=\"y714\" style=\"background:var(--color-content-bg);\"><button class=\"w-tabs-section-header with_icon\" aria-controls=\"content-y714\" aria-expanded=\"false\"><i class=\"fas fa-clipboard-list\"><\/i><div class=\"w-tabs-section-title\">\u00c7ekme Dayan\u0131m\u0131<\/div><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-y714\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"g-cols wpb_row us_custom_80ebc385 via_grid cols_2 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\" style=\"--columns-gap:3rem;\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-image us_custom_447bff20 has_ratio align_none\"><div class=\"w-image-h\"><div style=\"padding-bottom:100%\"><\/div><img decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.aokaifilters.com\/wp-content\/uploads\/2023\/09\/tensile-strength-test-1.jpg\" class=\"attachment-us_600_600 size-us_600_600\" alt=\"filter media tensile strength testing device\" loading=\"lazy\" title=\"\"><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><h3>Tensile Strength Test<\/h3>\n<p><strong>Tensile Strength Test<\/strong> is a measure of the directional strength of the media, measured in pounds per square inch. The sample is secured in the testing machine and is pulled apart to the point of failure. A resultant load-displacement curve is developed which is then compared to new material for residual property characteristics.<\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"w-tabs-section\" id=\"we21\" style=\"background:var(--color-content-bg);\"><button class=\"w-tabs-section-header with_icon\" aria-controls=\"content-we21\" aria-expanded=\"false\"><i class=\"fas fa-clipboard-list\"><\/i><div class=\"w-tabs-section-title\">Microscopic Analysis<\/div><div class=\"w-tabs-section-control\"><\/div><\/button><div  class=\"w-tabs-section-content\" id=\"content-we21\"><div class=\"w-tabs-section-content-h i-cf\"><div class=\"g-cols wpb_row us_custom_80ebc385 via_grid cols_2 laptops-cols_inherit tablets-cols_inherit mobiles-cols_1 valign_top type_default stacking_default\" style=\"--columns-gap:3rem;\"><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"w-image us_custom_447bff20 has_ratio align_none\"><div class=\"w-image-h\"><div style=\"padding-bottom:100%\"><\/div><img decoding=\"async\" width=\"1548\" height=\"995\" src=\"https:\/\/www.aokaifilters.com\/wp-content\/uploads\/sem-thermofisher.webp\" class=\"attachment-full size-full\" alt=\"\" loading=\"lazy\" title=\"\"><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container\"><div class=\"vc_column-inner\"><div class=\"wpb_text_column\"><div class=\"wpb_wrapper\"><h3>Microscopic Analysis<\/h3>\n<p>Visual analysis of a filter sample is aided by the use of a light microscope. In addition to observing the failure site, determining the particulate interaction with the filter media surface is often critical in solving filter media performance issues. Scanning Electron Microscopy (SEM) is also very helpful when investigating particulate and filter fiber surface morphology. Evidence of abrasion, chemical, and thermal effects is often enhanced during <strong>Microscopic Analysis<\/strong>.<\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section>","protected":false},"excerpt":{"rendered":"Giri\u015fSayfalarFilter Bag Testing &#038; AnalysisFilter Bag Testing &amp; AnalysisService Objectives Is your dust collector underperforming? Are you facing unexpected filter bag failures or struggling with high energy costs? Do you know what media to choose and when to replace your filter bags? Aokai Environtec&#8217;s Filter Bag Testing &amp; Analysis Service (also known as Filter Bag...","protected":false},"author":4,"featured_media":1942,"parent":2031,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16188","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.aokaifilters.com\/tr\/wp-json\/wp\/v2\/pages\/16188","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aokaifilters.com\/tr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.aokaifilters.com\/tr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.aokaifilters.com\/tr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aokaifilters.com\/tr\/wp-json\/wp\/v2\/comments?post=16188"}],"version-history":[{"count":0,"href":"https:\/\/www.aokaifilters.com\/tr\/wp-json\/wp\/v2\/pages\/16188\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.aokaifilters.com\/tr\/wp-json\/wp\/v2\/pages\/2031"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aokaifilters.com\/tr\/wp-json\/wp\/v2\/media\/1942"}],"wp:attachment":[{"href":"https:\/\/www.aokaifilters.com\/tr\/wp-json\/wp\/v2\/media?parent=16188"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}